The short answer
In one paragraph
Choose Visium, today usually Visium HD, when you want an unbiased, whole-transcriptome view: discovery work, no fixed gene list, or genes and species a panel won't cover. Choose Xenium when you know which genes matter and need true single-cell and subcellular resolution with real cell boundaries. The two work well together: Visium HD to find what changes, Xenium to map it cell by cell.
The core difference: sequencing vs imaging
Visium is sequencing-based. RNA (or probes bound to RNA) is captured on a slide covered in spatially barcoded oligonucleotides, turned into a library and sequenced. Each barcode marks a location, so the result is a count table of genes per spot or per square, aligned to an H&E or immunofluorescence image of the same section.
Xenium is imaging-based. Gene-specific probes bind RNA inside the tissue and are read out over repeated rounds of fluorescent imaging on the Xenium Analyzer. Every transcript gets its own x–y position, and cell segmentation assigns transcripts to cells. There is no sequencing step: the instrument returns the data directly.
That one difference drives most of the trade-offs. Sequencing gives breadth (every gene, in principle) at the cost of resolution and sequencing spend. Imaging gives precise positions and higher sensitivity for the genes you choose, at the cost of breadth.
The Visium family: which version?
“Visium” now covers several assays that share a name but differ in resolution, chemistry and the samples they accept.
| Version | Resolution | Chemistry and samples | Good to know |
|---|---|---|---|
| Visium (original, direct placement) | 55 µm spots, 100 µm apart; about 5,000 spots per 6.5 mm capture area | Poly-A capture for fresh frozen tissue; a probe-based version for FFPE | The section goes straight onto the Visium slide. Behind many published datasets; most new projects use the CytAssist versions. |
| Visium CytAssist | Same 55 µm spots; 6.5 mm (about 5,000 spots) or 11 mm (about 14,000 spots) capture areas | Probe-based whole transcriptome, human and mouse; FFPE, fresh frozen and fixed frozen | Sections are cut onto ordinary glass slides, and the CytAssist instrument transfers probes to the Visium slide. A Gene and Protein Expression option adds a panel of antibody-tagged proteins. |
| Visium HD | Continuous 2 µm barcoded squares, analyzed as 8 µm (recommended) or 16 µm bins; 6.5 mm capture area | Probe-based whole transcriptome, human and mouse; FFPE, fresh frozen and fixed frozen; requires CytAssist | Near single-cell resolution. Recent Space Ranger versions can segment cells from the H&E image and group squares into cells. |
| Visium HD 3′ | Same 2 µm squares as Visium HD | Poly-A capture, so not limited to human and mouse; fresh frozen tissue | Launched in 2025 for discovery in any species and for transcripts a probe panel doesn't cover. Needs roughly twice the sequencing depth of probe-based Visium HD. |
Choosing within Visium
- Human or mouse FFPE, single-cell-scale questions: Visium HD is the usual choice.
- Tissue-level questions, larger sections or tighter sequencing budgets: standard Visium CytAssist with 55 µm spots, especially the 11 mm capture area, can still be the better fit.
- Other species, or transcripts outside a probe panel: Visium HD 3′, provided you have fresh frozen tissue.
- Proteins alongside RNA: the CytAssist Gene and Protein Expression assay.
Keep sequencing in the budget from the start. A fully covered Visium HD capture area needs hundreds of millions of read pairs, far more than a 55 µm spot slide.
Xenium and its add-ons
Xenium measures a targeted panel. The main choices are which panel, how cells are segmented, and whether to add protein.
- Panels. Predesigned panels of a few hundred genes for specific tissues, the Xenium Prime 5K panels (about 5,000 genes, human or mouse), fully custom panels of up to 480 genes, and up to 100 custom genes added to a predesigned panel. A matched single-cell RNA-seq dataset makes custom panel design far more reliable.
- Multimodal cell segmentation kit. Alongside the DAPI nuclear stain, it adds cell boundary stains (ATP1A1, E-cadherin and CD45), an interior RNA stain (18S) and an interior protein stain (αSMA and vimentin). The onboard pipeline uses boundaries first, then the interior RNA stain, and falls back to expanding a fixed distance around each nucleus. The interior protein stain is for checking results by eye. In dense or irregular tissue, the kit makes a large difference to cell boundaries.
- Xenium Protein. Launched in 2025, it detects a panel of proteins (immune, tumour and proliferation markers) together with RNA in the same cells, on the same section, in one run. At launch it supported human FFPE tissue and RNA panels below 500 genes, so not the 5K panel. Check current compatibility before planning.
- Staining after the run. The same section can be H&E or immunofluorescence stained after Xenium and registered to the transcript map, which helps pathology review and region annotation.
Each run takes two slides, and the imaged area is large enough for whole sections, several smaller sections or tissue microarray cores. Xenium works with FFPE and fresh frozen tissue.
Visium HD vs Xenium side by side
| Visium HD | Xenium | |
|---|---|---|
| Readout | Sequencing | In situ imaging |
| Genes | Whole transcriptome (human and mouse probes), or any species with HD 3′ | Targeted: a few hundred genes up to about 5,000, plus custom genes |
| Resolution | 2 µm squares, usually analyzed as 8 µm bins or grouped into segmented cells | Individual transcript positions, assigned to segmented cells |
| Sensitivity | Broad but shallower per gene | Usually higher per gene for the genes on the panel |
| Tissue area | 6.5 × 6.5 mm per capture area | Larger areas per slide, often whole sections |
| Protein | Not on HD; the 55 µm CytAssist Gene and Protein assay offers it | Xenium Protein, in the same cells |
| Main cost drivers | Slides plus deep sequencing | Panel, slides and instrument time; no sequencing |
| Vendor software | Space Ranger, Loupe Browser | Xenium Onboard Analysis, Xenium Ranger, Xenium Explorer |
10x updates both platforms often. Treat these tables as orientation and confirm current specifications, sample compatibility and pricing with 10x Genomics or your core facility before committing.
Using Visium and Xenium together
The platforms complement each other well, and many studies use both on adjacent sections from the same blocks:
- Discover, then target. Use Visium HD to find the genes and regions that change, then design a Xenium custom panel or add-on around them.
- Breadth plus cell boundaries. Xenium gives clean cell types and neighbourhoods; Visium adds whole-transcriptome context, such as pathways, for the same regions.
- Shared references. Register both datasets to H&E images, and use the same single-cell reference for cell typing, so results can be compared directly.
How the analysis differs
- 55 µm Visium spots each hold several cells, so analysis centres on spatial domains, spatially variable genes and deconvolution (estimating the cell type mix per spot from a single-cell reference).
- Visium HD produces very large datasets. 8 µm bins don't follow cell boundaries, so either analyze bins with methods that allow for mixing, or group squares into segmented cells and check that against the H&E before cell typing.
- Xenium analysis lives or dies on segmentation. Check how many cells were segmented from boundary stains rather than nuclear expansion, review negative-control probes and transcripts per cell, then cell type by reference mapping checked against known markers.
- On every platform, patients or animals are the unit of replication, not spots, bins or cells. With hundreds of thousands of observations, almost any difference looks significant unless the statistics account for this.
Frequently asked questions
Is Visium HD single-cell?
Close, but not exactly. Its 2 µm squares are smaller than cells but don't follow cell boundaries. Grouping squares into segmented cells gives cell-level data with some mixing at the edges, whereas Xenium assigns individual transcripts to segmented cells.
Which Visium version should I use for FFPE samples?
For human or mouse FFPE, Visium HD is usually the best choice, with standard 55 µm Visium CytAssist as an option for tissue-level questions, larger areas or smaller sequencing budgets. Visium HD 3′ needs fresh frozen tissue.
Can I run Visium and Xenium on the same tissue?
Yes. The usual approach is adjacent serial sections from the same block, with both datasets registered to H&E images and cell typed against the same single-cell reference.
Is the Xenium Prime 5K panel enough for discovery?
It covers about 5,000 genes, which is enough for many discovery questions in human and mouse. For a truly unbiased view, other species or non-coding transcripts, Visium HD or HD 3′ is still the better fit.
Can you analyze Visium or Xenium data we already have?
Yes. We regularly start from Space Ranger or Xenium outputs, review QC and segmentation, and take the analysis through to figures and methods text.